Hydraulic fittings #2604 05/23/2021 10:32 PM
Joined: Jan 2019
Posts: 732
sonny Online Content OP
MBN old hand
OP Online Content
MBN old hand
Joined: Jan 2019
Posts: 732
What kind of solder do they use on fittings on the end of hyd. lines? Blew one end off the 340 back to the hitch lift,---- hitch is up with tiller hangin on it, cant lower it without pressure to release the valve block.
Got a REAL mess here now! ever see a 17 gpm pump at 2000 pounds+ pressure and 1900 rpm motor speed dump out a half inch hose?? Probably 2 or 3 gallons before I could hit the key to shut motor off!
The fitting was already leaking but did hope it didnt get worse before I got don tilling ----- well that didnt happen. Anyway the solder they had on there dont look like they had the fitting hot enough to sweat properly. Will regular solder hold?


"A machine you build yourself is a vote for a different way of life. There are things you have to earn with your hands."
Re: Hydraulic fittings [Re: sonny] #2605 05/24/2021 06:01 AM
Joined: Jan 2019
Posts: 355
B
bunkclimber Offline
MBN enthusiast
Offline
MBN enthusiast
B
Joined: Jan 2019
Posts: 355
no Sonny it has to be brazed on with brazing rod to contain the pressure..most refrigeration guys(Jim)are familiar with the process..clean and check the fitup of the joint then heat and flow the brazing rod into the joint..ordinary plumbing solder isnt up to the job..too soft

Re: Hydraulic fittings [Re: sonny] #2606 05/24/2021 09:25 AM
Joined: Jan 2019
Posts: 732
sonny Online Content OP
MBN old hand
OP Online Content
MBN old hand
Joined: Jan 2019
Posts: 732
AH HA! kinda wondered about that! ----well, this is just lead solder on these! Somebody up the line screwed up on these. I cant figure why they are copper fittings to start with. Dont think these are original IH parts here. All IH lines I been around have steel fittings on them. HMMMM! ---- the plot thickens! lol!


"A machine you build yourself is a vote for a different way of life. There are things you have to earn with your hands."
Re: Hydraulic fittings [Re: sonny] #2607 05/24/2021 11:07 AM
Joined: Jan 2019
Posts: 355
B
bunkclimber Offline
MBN enthusiast
Offline
MBN enthusiast
B
Joined: Jan 2019
Posts: 355
copper might be OK on the return side but then the fittings probably aren't right for each other either..the only common interchange with copper would be NPT pipe thread..most hydraulics use tapered flare or O-Ring nowadays,pipe thread is out the door,basically obsolete..well anyway good thing you caught it even if it broke-instead of sousing up your garden with hyd oil

Re: Hydraulic fittings [Re: sonny] #2608 05/25/2021 01:10 AM
Joined: Jan 2019
Posts: 732
sonny Online Content OP
MBN old hand
OP Online Content
MBN old hand
Joined: Jan 2019
Posts: 732
a pic of half of the manifold block and the short tubes with the fittings. you can see the solder job was shoddy and also the tube is kinda rough. Temporary fix for now will have to be clean and re sweat both fittings til I can figure a way around the bad tubes.
Cant find a used block with funky tubes like these and my hoses wont reach a block without them, so for now Hope it will hold for the season til I find a different way to connect the hoses to the block. I will probably have to get longer hoses too which is no problem.

Attached Files
DSCN0244.jpg (63.78 KB, 34 downloads)

"A machine you build yourself is a vote for a different way of life. There are things you have to earn with your hands."
Re: Hydraulic fittings [Re: sonny] #2609 05/25/2021 07:50 AM
Joined: Jan 2019
Posts: 355
B
bunkclimber Offline
MBN enthusiast
Offline
MBN enthusiast
B
Joined: Jan 2019
Posts: 355
Sonny,you need to completely clean the hardlines coming out of the block of all solder. (1)An easy fix would be to cut the soldered ends off the tubes,find or buy a pair of straight JIC to NPT adapters, fit them up in the 3-jaw chuck lathe you have (you do have it wired by now I hope) and turn the NPT threaded portion off,then backbore the JIC part to fit the tube INTO the hole you just made in the adapter and braze it onto the tube..this would give you JIC taper to fit a hose to on the end of your steel lines. Alternative Fix #2 would be to cut both steel lines off the pictured block and drill and tap the block NPT and thread a pair of NPT to JIC adapters right into the block..connect your hose there.

The JIC adapters are $2.05/each..this is why I always buy more than I need when purchasing,need two,buy four..the shipping is always the same, a couple spare fittings never broke the bank for me,and are worth much more when you need em'.

Additionally I just exploded the drive chain input to the transfer case of my mini articulated loader last evening, moving a tree..morse chain from the hydraulic motor to the transfer case input shaft just spins with no grip on the input sprocket..II think the transfer case is OK,the input sprocket and chain are worn out and will need replacing..very tight location in there,repair will have to wait as I have a lot going on right now..luckily was able to get the miniloader into neutral..got the onry 6000lb forklift and scooped it up and moved it to the pad in front of the barn for further inspection..the morse chain drive is meant to be a safety 'fuse' of sorts to protect the transfer case from damage..the cases have gotten VERY hard to find as of late..just one more piece of meat on the plate here to chew..Everyone have a safe Memorial Day..enjoy

Re: Hydraulic fittings [Re: sonny] #2617 06/01/2021 11:13 AM
Joined: Jan 2019
Posts: 732
sonny Online Content OP
MBN old hand
OP Online Content
MBN old hand
Joined: Jan 2019
Posts: 732
Cleaned and re-soldered the fittings and they are holding BUT one of the sub fittings is leaking. Cant get another full turn out of it and the tape is starting to leak. Need a straight swivel instead of the 45 degree they have on it. Might get the temporary fix to work yet. I am still looking for the right block to put on it and longer hoses to reach it.


"A machine you build yourself is a vote for a different way of life. There are things you have to earn with your hands."
Re: Hydraulic fittings [Re: sonny] #2657 06/28/2021 03:49 PM
Joined: Jan 2019
Posts: 732
sonny Online Content OP
MBN old hand
OP Online Content
MBN old hand
Joined: Jan 2019
Posts: 732
Got another idea on the problem block, -----un-hook the lift cylinder from that section of valve bank and hook directly into one of the side outlets and use 1 of the other handles instead of the drawbar valve. That would bypass the damaged valve.


"A machine you build yourself is a vote for a different way of life. There are things you have to earn with your hands."
Re: Hydraulic fittings [Re: sonny] #2661 07/02/2021 09:54 AM
Joined: Jan 2019
Posts: 730
JIM Offline
MBN old hand
Offline
MBN old hand
Joined: Jan 2019
Posts: 730
that's what I like to see....ADAPT and OVERCOME. grin


I know a lot about a lot of things BUT I still have a lot to learn.
Life is what you make of it. So, why not make a working machine to make it easier.
Re: Hydraulic fittings [Re: sonny] #2662 07/02/2021 04:52 PM
Joined: Jan 2019
Posts: 355
B
bunkclimber Offline
MBN enthusiast
Offline
MBN enthusiast
B
Joined: Jan 2019
Posts: 355
we like to call it a 'workaround'-as long as too many of them don't add up to dysfunction

Re: Hydraulic fittings [Re: sonny] #2663 07/02/2021 10:27 PM
Joined: Jan 2019
Posts: 732
sonny Online Content OP
MBN old hand
OP Online Content
MBN old hand
Joined: Jan 2019
Posts: 732
I would rather have the cylinder hooked to the regular valve anyhow! ---- then I would have smooth precise control instead of the jerky poor control of the drawbar valve.


"A machine you build yourself is a vote for a different way of life. There are things you have to earn with your hands."
Re: Hydraulic fittings [Re: sonny] #2664 07/06/2021 01:49 PM
Joined: Jan 2019
Posts: 732
sonny Online Content OP
MBN old hand
OP Online Content
MBN old hand
Joined: Jan 2019
Posts: 732
Blew the line fitting AGAIN! ----- gotta route the lift cylinder to one of the other valves and not use the one with the check valves in it! ---- They are making too much pressure in the line and blowing things apart!


"A machine you build yourself is a vote for a different way of life. There are things you have to earn with your hands."
Re: Hydraulic fittings [Re: sonny] #2676 07/29/2021 01:50 AM
Joined: Jan 2019
Posts: 732
sonny Online Content OP
MBN old hand
OP Online Content
MBN old hand
Joined: Jan 2019
Posts: 732
Havent had time to work on the 340 yet --- gotta happen soon cause I need it on the tater digger!


"A machine you build yourself is a vote for a different way of life. There are things you have to earn with your hands."

Recent Topics
Gardens for 2021
by sonny - 07/30/2021 12:06 PM
Hydraulic fittings
by sonny - 07/29/2021 01:50 AM
5 bar hay rakes
by chma - 07/20/2021 09:48 PM
F-700 bucket truck
by bunkclimber - 07/11/2021 08:33 PM
ShoutChat Box
Comment Guidelines: Do post respectful and insightful comments. Don't flame, hate, spam.
Today's Birthdays
There are no members with birthdays on this day.
Donation Box
Powered by UBB.threads™ PHP Forum Software 7.7.3