Sonny you have air over hydraulic to maintain the electrical insulation of the bucket, no metallic links (wires,hoses or cables) thru the fibreglass boom to the truck..the air lines are plastic so they don't conduct electricity..the plastic lines get cracks in them occasionally makes for difficult troubleshooting